Nevada's C-2 is the full electrical contracting classification, issued by the Nevada State Contractors Board (NSCB). Getting it means a qualified individual with four years of electrical experience, an application with a financial statement, two PSI exams — the C-2 trade exam, open book on the 2017 National Electrical Code, and the Construction Management Survey (CMS), both offered in Spanish — and a bond the Board sets at approval. This guide uses only what the NSCB, Nevada law and PSI's current bulletin publish.

The path at a glance
4 yrsElectrical experience in the classification, within the last 15 years
80 / 4 hC-2 trade exam: 56 correct to pass
NEC 2017Code edition the C-2 exam is written to, allowed in the room
ESC-2 and CMS exams offered in Spanish by PSI
PSI — Nevada “C” Classification Candidate Information Bulletin (updated 3/25/2026); Nevada State Contractors Board — License Requirements
Step by step

Who needs a Nevada contractor license

NRS 624.020 defines a contractor broadly: anyone who undertakes or offers to construct, alter, repair, add to, subtract from, improve, move, wreck or demolish any building or other structure, including subcontractors and specialty contractors, and construction managers paid a professional fee. The Board requires the license before you contract — before you bid, offer to engage or negotiate a price. The small-job exemption in NRS 624.031(6) is narrow: work to repair or maintain property worth less than $1,000 in labor and materials, and only if no building permit is required, the work is not the type done by plumbing, electrical, refrigeration, heating or air-conditioning contractors or by another classification the Board treats as significantly affecting public health and safety, and it is not part of a larger project worth $500 or more or split into smaller contracts to evade the law.

What the C-2 license covers

NAC 624.200 makes C-2 the specialty of electrical contracting. A C-2 licensee may install any electrical wires, fixtures, appliances, apparatuses, raceways and conduits; may install, modify and maintain wind-energy systems for residential and commercial installations that are not scaled or intended solely for the commercial production and sale of electricity; and may do any work of the C-2 subclassifications. Those subclassifications are C-2a Electrical Wiring, C-2b Integrated Ceilings, C-2c Fire Detection, C-2d Low Voltage Systems, C-2e Lines to Transmit Electricity, C-2f Residential Wiring and C-2g Photovoltaics — narrower licenses with their own PSI exams, so be sure which one you are applying for.

Electrical work never fits the small-job exemption described above: NRS 624.031(6) excludes work of the type performed by an electrical contractor regardless of its price. And a general building contractor may not take on electrical work without the specialty license (NRS 624.215(3)), apart from a narrow small-work exception in NRS 624.220(4).

The qualified individual and the four-year rule

Nevada licenses the business — the license belongs to the business, not to the qualifying person — but every license rests on a trade qualified individual. Under NRS 624.260, as the Board's requirements page explains, that person can be an owner, officer, member, manager or employee, must be a bona fide member or employee of the company, and must be actively engaged in its contracting business. The experience rule is specific: within the fifteen years immediately before the application is filed, at least four full years as a journeyman, foreman, supervising employee or contractor in the specific classification requested — here, the C-2 Electrical classification. The application also lets one company split the role: a management qualifier, who must pass the construction management exam, and a trade qualifier, who meets the experience and trade-exam requirement — or one person who does both.

The Board accepts three kinds of proof: four Certification of Work Experience forms for each trade qualifier, filled out by current or former employers, general contractors, subcontractors or customers — one per company, and relatives only if they were your employer — which together must add up to at least four full years (1,460 days), though no single certificate has to cover all four; a current master's certification issued by a government agency in a substantially similar discipline; or proof of transferable military experience and training. Every qualifier also files a Resume of Experience, and self-employed experience needs a list of customers with their addresses and phone numbers. There is no education requirement, but training in a program at an accredited college, university or equivalent program accepted by the Board can count for up to three of the four years, documented with apprenticeship certificates or transcripts.

The application, the financial statement and the bond

The application goes to the NSCB with a nonrefundable $300 application fee and a principal's signature, together with the experience documents, a resume, copies of government IDs, and a background disclosure and fingerprint form for every person listed; PSI's bulletin adds that each applicant submits fingerprints for a state and national fingerprint-based criminal history check. Examination fees are separate and are paid to PSI, not to the Board.

A financial statement is required whatever the size of your work, because the Board puts a monetary limit on every license — under NRS 624.220, the maximum contract you may undertake on one or more construction contracts on a single construction site or subdivision site for a single client. The limit you request decides the kind of statement: at $25,000 or less, a CPA-prepared statement, the Board's own business or personal financial statement form, or an accounting-software balance sheet with an affidavit; above $25,000 and below $500,000, a CPA-compiled statement current within six months, or a reviewed or audited one current within a year; from $500,000 to below $1,000,000, a compiled statement with full disclosures, or a reviewed or audited one; at $1,000,000 or more, reviewed or audited by an independent CPA. A Bank Verification Form completed by your bank goes with it.

The bond comes last. The Board fixes the amount at license approval — anywhere from $1,000 to $500,000, depending on the type of license, the monetary limit, financial responsibility, experience and character — and you post it as a surety bond or a cash deposit before the license issues. A cash deposit carries a $200 biennial administrative fee and is held for two years after the license ends.

Two exams: the C-2 trade exam and the CMS

The NSCB requires every applicant to pass the CMS business-and-law exam and a trade exam for the classification, both administered by PSI. PSI's “C” Classification bulletin (updated 3/25/2026) sets the C-2 Electrical Contractor exam at 80 questions, 4 hours and a minimum passing score of 56. It is open book: the references allowed in the room are the 2017 National Electrical Code (or the 2017 NEC Handbook) and NFPA 72, the National Fire Alarm Code, in its 2010 or 2013 edition (or its handbook). Code questions are based only on the listed edition — so study the 2017 NEC, not a newer cycle.

The subject areas are published: Conductors and Cables 8, Safety Information 8, Service, Feeders and Branch Circuits 7, Grounding and Bonding 7, Raceways and Boxes 7, General Electrical Knowledge 6, Electrical Power 6, Motors 6, Lighting 5, Special Occupancies and Equipment 5, Transmission Lines 5, Overcurrent Protection 4, Low Voltage 2, Illuminated Signs 2, and Fire Detection and Alarm Systems 2. Some books behind the questions may not be brought in — Ugly's Electrical References, 29 CFR Part 1926 (OSHA construction standards), the 2012 National Electrical Safety Code and the Lineman's and Cableman's Handbook — which matters for the eight safety items and the five on transmission lines. Bring your own copies of the allowed books. You may highlight, underline and index them before the exam and use permanent tabs, but you may not write in them, sticky notes must come out, and loose papers are confiscated. A silent, non-printing, non-programmable calculator is allowed.

The CMS is 60 scored questions plus 3 unscored, 120 minutes, 45 correct (75 percent) to pass, open book with PSI's Construction Business and Law Manual for Nevada — see our Nevada CMS guide.

When the trade exam can be waived

NAC 624.600 lets the Board waive the exam for someone who passed an exam offered by an endorsing state the Board has approved, or a NASCLA-accredited exam the Board finds substantially equivalent. Endorsement requires active licensure in the endorsing state for the past four years with no discipline, a Request for Verification of Licensure completed by that state, and a match on the Board's State Equivalency Chart; if that state has no equivalent trade exam, you take Nevada's. The Board's pages also describe a waiver for qualifiers who recently served on another Nevada license in the same classification, but they state the look-back period differently from page to page, so confirm yours with the Board. It reserves the right to require an exam of any applicant.

Taking the exams in Spanish

In a news release dated December 9, 2025, the NSCB announced that PSI offers Spanish-language exams for 13 classifications and the Construction Management Survey, and PSI's current bulletin lists the same exams. C-2 Electrical is on the list — so is C-2d Low Voltage — and so is the CMS, so a C-2 applicant can take both required exams in Spanish. To switch a listed exam from English to Spanish, PSI's bulletin says to call PSI at (855) 205-5827 or email examschedule@psionline.com. The code book in the room is the English 2017 NEC, so learn the English article titles and terms along with the Spanish.

Scheduling with PSI, fees and retakes

You cannot book an exam until the Board has your application and has verified the experience. It then issues an Examination Eligibility form with a Candidate ID — the application packet says it is mailed to the business's mailing address, not the qualifier's home — and you register with PSI online at test-takers.psiexams.com/nvcon or by phone. PSI charges $95 for one examination portion and $140 for two when the second one is the CMS (two trade exams are $95 each); registration fees are not refundable or transferable and expire with your eligibility. Cancel or reschedule at least two days before the appointment, arrive 30 minutes early, and bring one valid, unexpired government photo ID whose name matches your registration — otherwise the fee is forfeited.

Tests run on computer at PSI centers in Las Vegas, Reno and Elko, and PSI's Nevada exams can also be taken at PSI sites in other states. Your score is given when you finish; a failing report shows strengths and weaknesses by area. After a failure you wait two weeks before retaking that portion. NAC 624.600 allows three attempts and requires the qualifier to pass within six months after the application is filed; a third failure voids the application, and you may apply again with a new application and fee 30 days or more after the last exam.

License fee, term and renewal

NAC 624.130 sets the Board's fees: $600 to issue or renew a license, and $150 for filing an active license's renewal late. Under NRS 624.283 a license expires two years after it is issued, and a license not renewed on or before its renewal date is automatically suspended. The bond must stay continuous the whole time: a surety can cancel only on 60 days' notice to the Board, and failing to keep the bond in force is cause to suspend or refuse to renew the license.

How to prepare

The Board is plain about preparation: it does not recommend or endorse any licensing school, it offers no practice exams of its own, and it points candidates to the reference list in each content outline. For C-2 that means the 2017 NEC is both the textbook and the tool: most areas — conductors, services and feeders, grounding and bonding, raceways and boxes, overcurrent protection, special occupancies — are NEC navigation plus calculation, so tab the articles and practice table lookups against the clock. Four hours for 80 questions is generous only if you can find things quickly. Study OSHA and line-work material separately, because those books stay outside.

LICENA's Nevada C-2 practice bank is 500 questions in five blocks mapped to PSI's 15 subject areas, every answer explained, in English, Spanish and Russian, with a free sample and no sign-up. The Nevada CMS bank covers the business-and-law exam.

FAQ

Nevada C-2 license — questions and answers

What is on the Nevada C-2 Electrical exam?
80 questions in 4 hours with 56 correct needed to pass, open book with the 2017 National Electrical Code (or its handbook) and NFPA 72 (2010 or 2013). The heaviest areas are Conductors and Cables and Safety Information (8 each), then Service, Feeders and Branch Circuits, Grounding and Bonding, and Raceways and Boxes (7 each).
Can I take the C-2 exam in Spanish?
Yes. The NSCB's December 9, 2025 news release and PSI's current bulletin list C-2 Electrical among the exams offered in Spanish, along with the CMS. To switch from English, call PSI at (855) 205-5827 or email examschedule@psionline.com.
Do I need the CMS as well?
Yes. The NSCB requires each applicant to pass the CMS business-and-law exam and the trade exam for the classification. PSI charges $140 when the two are registered together, or $95 for one portion.
Is C-2 the same as C-2a or C-2f?
No. NAC 624.200 lists seven C-2 subclassifications — including C-2a Electrical Wiring, C-2d Low Voltage, C-2f Residential Wiring and C-2g Photovoltaics — each a narrower license with its own PSI exam. A full C-2 holder may do the work of all of them.
How much experience do I need?
The trade qualifier needs at least four full years as a journeyman, foreman, supervising employee or contractor in the C-2 classification within the fifteen years before the application, usually documented on four Certification of Work Experience forms totaling at least 1,460 days. Accredited training can count for up to three of the four years.
LICENA

Ready to practice for the exams? The Nevada C-2 Electrical practice bank on LICENA: 500 questions mapped to PSI's subject areas, with a written explanation on every answer, in English, Spanish and Russian. The sample is free — no sign-up.

Try the free practice test → Nevada CMS practice
Official sources